Connexion client options: Difference between revisions

mNo edit summary
m (→‎Settings: struck through obsolete instructions)
 
(29 intermediate revisions by 4 users not shown)
Line 2: Line 2:


==Settings==
==Settings==
Before opening the Options dialog in Connexion, navigate to '''Cataloging (I:)/Connexion/LocalSaveFiles''', and create a folder named with your initials, i.e. I:/Connexion/LocalSaveFiles/ABC, if you have not already done so. This is the folder where your import and export files will be stored by Connexion (see Export heading below) and [[Setting preferences in Voyager|Voyager]].
Before opening the Options dialog in Connexion upon initial set-up:
* <strike>Catalogers should navigate to '''Cataloging (I:)/Connexion/LocalSaveFiles''', and create a folder named with your initials, e.g., I:/Connexion/LocalSaveFiles/ABC, if you have not already done so.</strike>
* Acquisitions staff should navigate to '''Acquisitions (J:)/Connexion/LocalSaveFiles''', and create a folder named with your initials, e.g., J:/Connexion/LocalSaveFiles/ABC, if you have not already done so.  
This is the folder where your import and export files will be stored by Connexion (see Export heading below) and [[Setting preferences in Voyager|Voyager]].  


You should also create an empty export file at this point to prepare for future record exports. There are two main ways to do this: from the Export tab in the Options dialog (see below), or from the Local File Manager dialog:
:From the drop-down "File" menu in Connexion, click on '''Local File Manager'''.
:Click the '''Create File''' button, and navigate to the folder with your initials. (You can also create a new folder at this point, if you did not do this previously.)
:In the '''File name''' bar, enter your initials (or another name for your save file if desired).
:Click the '''Open''' button, and Connexion will create a .db file and add its path in the Local File Manager dialog. (Note: Connexion automatically appends an infix to your file name to designate the type of records in the save file - for instance, SEH.bib.db or AuthorityConstantData.authcd.db. This may make the file look like a different format, but it is a .db file!)
:You can then click the '''Set as Default''' button to designate this as your default save file (recommended, if this is your main save file), or simply save the file path for later.
===Options===
Once you have a local save folder, go to Tools > Options in Connexion.  
Once you have a local save folder, go to Tools > Options in Connexion.  


====Access====
====Access====
:Retain default settings
:Retain default settings
====Authorizations====
====Authorizations====
:Enter your authorization number and password, and a nickname for your login, if you want (this is not required, it just saves you from having to manually enter your authorization and password every time).
:Enter your authorization number (no hyphens),  password, and name, and make that the default login.
 
====Batch====
====Batch====
:Retain default settings
:Retain default settings
====Classify====
====Classify====
:Retain default settings
:Retain default settings
====Derive Record====
====Derive Record====
(Catalogers only)
:'''Bibliographic records and constant data'''
:'''Bibliographic records and constant data'''
:: Recommended: 04X, 05X, 1XX, 3XX, 4XX, 5XX, 6XX, 7XX, 8XX
:: Recommended: 04X, 05X, 1XX, 2XX, 3XX, 4XX, 5XX, 6XX, 7XX, 8XX
::However, choose whichever settings work for you, based on the nature of your work.
::However, choose whichever settings work for you, based on the nature of your work.
====Export====
====Export====
:Click "Create" > "File"
:<strike>Click "Create", make sure that the radio button for "File" is selected, and click "OK". This will open a file dialog box. Navigate to I:\Connexion\LocalSaveFiles\[your initials] (for catalogers) or J:\Connexion\LocalSaveFiles\[your initials] (for acquisitions staff) if you are not already there.
::Navigate to I:\Connexion\LocalSaveFiles\[your initials] and create .DAT file.  
:Create a .DAT file by entering a filename in the "File name" box, and click "Open". Another dialog box will open, showing the file path; click "OK".
::You can create multiple .DAT files, and name them whatever you want. Note that whichever .DAT file path is highlighted is your default save file.
:You can create multiple .DAT files, and name them whatever you want (popular choices include your initials and "test"). Note that whichever .DAT file path is highlighted is your default save file.
:If preferred, you can highlight the "File:(Prompt for filename)" option. This will allow you to choose which .DAT file to write to whenever you export a record.
:Once you're finished, make sure to click "Apply" to save your changes.</strike>
 
:See Sharepoint Collections > Systems > TIND > Internal documentation
 
:'''Record characteristics'''
:'''Record characteristics'''
::For both Bibliographic and Authority records:
::For both Bibliographic and Authority records:
::Record Standard: MARC 21
::Record Standard: MARC 21
::Character Set: MARC-8
::Character Set: UTF-8 Unicode (this is different from Voyager, which used MARC-8)
:'''Field export options'''
:'''Field export options''' (fields to delete upon export)
::Bibliographic: 011,012,029,035,049,084,776,900-994  
::'''Acquisitions:''' Bibliographic: 003, 006, 007, 010-099, 210, 222, 242, 247, 306-321, 342-388, 400-499, 500-509, 511-599, 600-699, 700-799, 800-899, 900-994
::'''Cataloging''' Bibliographic: 003, 011, 012, 029, 049, 084, 776, 900-994
 
====Fonts====
====Fonts====
:Retain default settings, or choose a font that works for you.
:Recommended: Arial Unicode MS, Lucida Unicode Sans, or other Unicode font (to be able to display diacritics and special characters correctly)
 
====General====
====General====
:Retain default settings
:Retain default settings or edit according to personal taste
 
====International====
====International====
:'''Export''': select radio button for "Include all data, with other scripts in 880 fields".
:'''Export''': select radio button for "Include all data, with other scripts in 880 fields".
====My Status====
====My Status====
:Retain default settings
:Add initials (and year-month, if desired) to Bibliographic Records and Authority Records
 
====Printing====
====Printing====
:Retain default settings
:Retain default settings
====RDA====
====RDA====
:Select both "Use RDA workforms when creating new bibliographic records" and "Use RDA workforms when creating new bibliographic records".
(Catalogers only)
:Select "Enable the RDA Toolkit" and enter the Folger's username and password (check with the Head of Collection Information Services if you do not have these).
:Modern materials: select both "Use RDA workforms when creating new bibliographic records" and "Use RDA workforms when creating new authority records".
:Early materials: select "Use RDA workforms when creating new authority records"
:Select "Enable the RDA Toolkit" and enter the Folger's username and password (check with the Associate Librarian for Collection Description and Imaging if you do not have these).
 
====Record Display====
====Record Display====
:Retain default settings
:Retain default settings or edit according to personal taste
 
====Spelling====
====Spelling====
:'''Customize Fields''' > '''Fields to Check'''
:'''Customize Fields''' > '''Fields to Check'''
::Recommended: 100 (skip subfields ab), 245, 246, 260, 264, 300, 368, 370, 372, 374, 490, 500, 502, 504, 505, 510, 530, 533, 546, 585, 667, 670, 740, 751, 752.
::Recommended for modern materials: 100 (skip subfields ab), 245, 246, 260, 264, 300, 368, 370, 372, 374, 490, 500, 502, 504, 505, 510, 530, 533, 546, 585, 667, 670, 740, 751, 752.
::Add additional fields as needed.
::Recommended for early modern printed materials: 300, 368, 370, 372, 374, 500, 502, 504, 505, 510, 530, 533, 546, 585, 667, 670, 751, 752.
::Recommended for early modern manuscripts and drawings: 100 (skip subfields ab), 245, 246, 300, 368, 370, 372, 374, 500, 502, 504, 505, 510, 520 (skip subfield u), 530, 533, 546, 585, 667, 670, 751, 752.
::Add or delete fields as needed.
 
====Toolbar====
====Toolbar====
:Retain default settings
:Retain default settings or edit according to personal taste
 
====Z39.50====
====Z39.50====
:Retain default settings
:Retain default settings


===Search WorldCat===
When searching for copy:
* In the "Search WorldCat" screen, check-mark "Apply Language of Cataloging Limiter" and "English" as the language of cataloging. (Only uncheck it if you do not find an English-language record for the item; it's okay to start with a non-English-language record as a last resort).
* BEWARE: the "Not Internet" setting does not work properly.  It should exclude records where the MARC 856 links to the resource itself, but in fact it also excludes records where the MARC 856 links to "version of resource" (See OCLC# 726942324 for an example: The 007 is for Graphic material, not Electronic resource;  the 856 is correctly coded to indicate the link is to a version of the resource, not the resource represented by the bibliographic record). [Verified as still true 2020-05-11 EB.]
[[Category:Acquisitions]]
[[Category:Cataloging]]
[[Category:Cataloging]]
[[Category:Connexion]]
[[Category:Connexion]]
Line 76: Line 123:


==See also==
==See also==
*[[Connexion client]]
* [[Setting preferences in Voyager]]
* [[Setting preferences in Voyager]]


[[Category:Cataloging]]
[[Category:Cataloging]]
[[Category:Staff policies and procedures]]
[[Category:Staff policies and procedures]]

Latest revision as of 14:25, 5 August 2024

The first time you use the Connexion client, go to Tools > Options to customize your "profile" to match Folger practice and your preferences. You can also create custom macros, text strings, and "User Tools." To avoid having to re-do the options when moving to a new computer, you'll need to copy your existing profile to the new computer.

Settings

Before opening the Options dialog in Connexion upon initial set-up:

  • Catalogers should navigate to Cataloging (I:)/Connexion/LocalSaveFiles, and create a folder named with your initials, e.g., I:/Connexion/LocalSaveFiles/ABC, if you have not already done so.
  • Acquisitions staff should navigate to Acquisitions (J:)/Connexion/LocalSaveFiles, and create a folder named with your initials, e.g., J:/Connexion/LocalSaveFiles/ABC, if you have not already done so.

This is the folder where your import and export files will be stored by Connexion (see Export heading below) and Voyager.

You should also create an empty export file at this point to prepare for future record exports. There are two main ways to do this: from the Export tab in the Options dialog (see below), or from the Local File Manager dialog:

From the drop-down "File" menu in Connexion, click on Local File Manager.
Click the Create File button, and navigate to the folder with your initials. (You can also create a new folder at this point, if you did not do this previously.)
In the File name bar, enter your initials (or another name for your save file if desired).
Click the Open button, and Connexion will create a .db file and add its path in the Local File Manager dialog. (Note: Connexion automatically appends an infix to your file name to designate the type of records in the save file - for instance, SEH.bib.db or AuthorityConstantData.authcd.db. This may make the file look like a different format, but it is a .db file!)
You can then click the Set as Default button to designate this as your default save file (recommended, if this is your main save file), or simply save the file path for later.

Options

Once you have a local save folder, go to Tools > Options in Connexion.

Access

Retain default settings

Authorizations

Enter your authorization number (no hyphens), password, and name, and make that the default login.

Batch

Retain default settings

Classify

Retain default settings

Derive Record

(Catalogers only)

Bibliographic records and constant data
Recommended: 04X, 05X, 1XX, 2XX, 3XX, 4XX, 5XX, 6XX, 7XX, 8XX
However, choose whichever settings work for you, based on the nature of your work.

Export

Click "Create", make sure that the radio button for "File" is selected, and click "OK". This will open a file dialog box. Navigate to I:\Connexion\LocalSaveFiles\[your initials] (for catalogers) or J:\Connexion\LocalSaveFiles\[your initials] (for acquisitions staff) if you are not already there.
Create a .DAT file by entering a filename in the "File name" box, and click "Open". Another dialog box will open, showing the file path; click "OK".
You can create multiple .DAT files, and name them whatever you want (popular choices include your initials and "test"). Note that whichever .DAT file path is highlighted is your default save file.
If preferred, you can highlight the "File:(Prompt for filename)" option. This will allow you to choose which .DAT file to write to whenever you export a record.
Once you're finished, make sure to click "Apply" to save your changes.
See Sharepoint Collections > Systems > TIND > Internal documentation
Record characteristics
For both Bibliographic and Authority records:
Record Standard: MARC 21
Character Set: UTF-8 Unicode (this is different from Voyager, which used MARC-8)
Field export options (fields to delete upon export)
Acquisitions: Bibliographic: 003, 006, 007, 010-099, 210, 222, 242, 247, 306-321, 342-388, 400-499, 500-509, 511-599, 600-699, 700-799, 800-899, 900-994
Cataloging Bibliographic: 003, 011, 012, 029, 049, 084, 776, 900-994

Fonts

Recommended: Arial Unicode MS, Lucida Unicode Sans, or other Unicode font (to be able to display diacritics and special characters correctly)

General

Retain default settings or edit according to personal taste

International

Export: select radio button for "Include all data, with other scripts in 880 fields".

My Status

Add initials (and year-month, if desired) to Bibliographic Records and Authority Records

Printing

Retain default settings

RDA

(Catalogers only)

Modern materials: select both "Use RDA workforms when creating new bibliographic records" and "Use RDA workforms when creating new authority records".
Early materials: select "Use RDA workforms when creating new authority records"
Select "Enable the RDA Toolkit" and enter the Folger's username and password (check with the Associate Librarian for Collection Description and Imaging if you do not have these).

Record Display

Retain default settings or edit according to personal taste

Spelling

Customize Fields > Fields to Check
Recommended for modern materials: 100 (skip subfields ab), 245, 246, 260, 264, 300, 368, 370, 372, 374, 490, 500, 502, 504, 505, 510, 530, 533, 546, 585, 667, 670, 740, 751, 752.
Recommended for early modern printed materials: 300, 368, 370, 372, 374, 500, 502, 504, 505, 510, 530, 533, 546, 585, 667, 670, 751, 752.
Recommended for early modern manuscripts and drawings: 100 (skip subfields ab), 245, 246, 300, 368, 370, 372, 374, 500, 502, 504, 505, 510, 520 (skip subfield u), 530, 533, 546, 585, 667, 670, 751, 752.
Add or delete fields as needed.

Toolbar

Retain default settings or edit according to personal taste

Z39.50

Retain default settings

Search WorldCat

When searching for copy:

  • In the "Search WorldCat" screen, check-mark "Apply Language of Cataloging Limiter" and "English" as the language of cataloging. (Only uncheck it if you do not find an English-language record for the item; it's okay to start with a non-English-language record as a last resort).
  • BEWARE: the "Not Internet" setting does not work properly. It should exclude records where the MARC 856 links to the resource itself, but in fact it also excludes records where the MARC 856 links to "version of resource" (See OCLC# 726942324 for an example: The 007 is for Graphic material, not Electronic resource; the 856 is correctly coded to indicate the link is to a version of the resource, not the resource represented by the bibliographic record). [Verified as still true 2020-05-11 EB.]

Transferring settings to a new computer

Connexion client options, macros, text strings, logins, toolbar preferences, search history, keymaps, display settings, etc. are stored on the C: drive of each computer you use, and are associated with your Folger network login (not your OCLC login). This lets people on shared computers customize Connexion the way they want. It also means that if you move to a new computer, you either have to reset all your customizations, or you have to copy your Connexion user profile from a computer that already has it set up. Note: This will not affect the settings and options of other people who use that computer; their Profiles are saved in a C: drive folder under their username that only they can access.

Windows XP

  1. While logged in to a computer that has the Connexion settings you want to copy, navigate to your OCLC user profile folder at C:\Documents and Settings\username\Application Data\OCLC\Connex\Profiles, but replace "username" with the username you use to log in to Folger computers (the "Application Data" folder is hidden by default, so you might first need make it visible: Tools > Folder Options > View > Files and Folders > Hidden files and folders > Show hidden files and folders).
  2. You should see a folder named "MyProfile." Copy this folder to a temporary location in your personal network drive (H:\)
  3. If you are moving from an XP machine to a Windows 7 machine, go to the "Windows 7" instructions, below.
  4. Log in to the new computer and launch Connexion (this will automatically create the folder and file referred to in the next step).
  5. Find the same location in the C:\ drive (C:\Documents and Settings\username\Application Data\OCLC\Connex\Profiles where "username" is the username you use to log in to Folger computers).
  6. Delete the "MyProfile" folder on the new computer.
  7. Copy the "MyProfile" folder from its temporary location on your H:\ network drive to the C:\ drive on the new computer.

Windows 7

  1. While logged in to a computer that has the Connexion settings you want to copy, navigate to your OCLC user profile folder at C:\Users\username\AppData Data\Roaming\OCLC\Connex\Profiles, but replace "username" with the username you use to log in to Folger computers (the "AppData" folder is hidden by default, so you might first need make it visible: Control Panel > Appearance and Personalization > Folder Options > View > Show hidden files, folders, and drives).
  2. You should see a folder named "MyProfile." Copy this folder to a temporary location in your personal network drive (H:\)
  3. Log in to the new computer and launch Connexion (this will automatically create the folder and file referred to in the next step).
  4. Find the same location in the C:\ drive (C:\Users\username\AppData Data\Roaming\OCLC\Connex\Profiles where "username" is the username you use to log in to Folger computers).
  5. Delete the "MyProfile" folder on the new computer.
  6. Copy the "MyProfile" folder from its temporary location on your H:\ network drive to the C:\ drive on the new computer.

See also